Installing & Removing Combination Filter The Air Cleaner will beep for 30 seconds and the Replace HEPA light will flash continuously indicating that is time to replace your filter. Replace the filter according to the directions then restart the system. See specification model instructions (E-7/E-8). Depending on usage, filter will last approximately 6 months. 1. Turn off & unplug the unit. 2. Press the Lock 7 Release Button & remove the Rear Cover from the unit. 3. Remove the used Combination Filter (Filter C) & dispose of it in the garbage. 4. Insert filter system into the unit. Consult the arrow on the filter for correct installation direction. 5. Reattach the Rear Cover of the unit & securely latch into place. Operating Instructions Before Operating the Air Purifier 1. Select a firm, level & flat location for the air purifier. For proper air flow, locate the unit at least 1 foot from any wall or furniture. Make sure none of the grills are blocked. 2. Plug the power cord into a 120V AC outlet. Important: When moving the air purifier, always lift unit by carrying handle located on back. Operating the Air Purifier (AC5350 Series) 1. Turn unit power ON. 2. Select fan speed Mode 1 – 5 1 = Low, ultra quiet sleep mode; 5 = High speed allergen control (Default setting is 5) 3. Select UV-C ON or OFF using UV-C Mode Button. 4. Timer: If you prefer to run the purifier for a specific number of hours, you can select between 1 & 8 hours on the display. Filter Replacement Indicator: The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter. Replace the filter according to directions (E-6) then press and hold the Timer button for 3 seconds to restart the system. UV Bulb Replacement Indicator: The circular blue light on the front panel of the purifier will flicker when it's time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold UV-C button for 3 seconds to reset the system. Control Panel Beep / Sound: The sound emitted from pressing the buttons on the control panel can be turned off / on by holding the Speed button for 3 seconds. Installing & Removing UV-C Bulb 1. Remove the Rear Cover of the unit by pushing Lock & Release Button. 2. After removing the Rear Cover from the unit, remove the Combination Filter. 3. After removing the Combination Filter, use a Philips head screwdriver to remove 2 screws & detach the UV-C Metal Shield. 4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue & pulling the bulb straight out of the unit. 5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit. Cleaning & Maintaining the Combination Filter The air purifier should be cleaned at least once every month and the outer Pre- / Charcoal Filter attached to the HEPA Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions. Pre- / Charcoal Filter Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. True HEPA Filter Remove the Combination Filter from the back of unit. Remove the Pre- / Charcoal Filter to expose the HEPA filter. When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA filter is still white, it does Not need to be replaced. Important: Do Not try to wash and re-use the Combination Filter. Air Purifier Use a clean, dry, soft cloth to wipe the external surface of the unit. |